Chesterton Connect™ System

Simplified Pressure, Vibration, and Temperature Equipment Monitoring System
The Chesterton Connect System is a simplified cloud-based equipment monitoring solution that provides 24/7 visibility of an equipment’s condition. This real-time equipment monitoring can help you to correlate and identify anomalies early to make operational improvements that increase reliability and minimize unplanned downtime. 
 
The Chesterton Connect System is geared towards pumps and sealing systems but can also be used to monitor vibration on other rotating equipment such as motors and gearboxes. 
 

Product Features

Chesterton Connect System makes it easy to safely monitor:

  • Process temperature
  • Process pressure
  • 3-Axis vibration (Acceleration, Peak, and Velocity RMS)
  • Surface temperature Replaceable battery

Hardware Technical Specifications


Chesterton Connect Sensor™ Operating Parameters

Pressure sensor limit: 1 bar g – 68 bar g (-14.7 psig – 1000 psig)
Temperature limit (body): -20°C – 85°C (-4°F – 185°F)
Temperature limit (sensor): -20°​C - 125°C (-4°F - 257°F)
Vibration sensor: 3-axis accelerometer ±16g
Battery: 3.6V lithium thionyl chloride battery (replaceable)
Fitting: 1/4" NPT 17-4PH connection
Mount: Magnetic mounting base (additional mounting options sold separately)
Certifications: FCC, IC, RoHS, IP66, NSF61, ACS


Hazardous Areas Option

Certifications:

ATEX/IECEx:
II 1 G Ex ia IIB T4 Ga
II 1 D Ex ia IIIB T200 166°C Da

Zone:
Class I Zone 0 AEx ia IIB T4 Ga
Zone 20 AEx ia IIIB T166°C Da

Division:
Class I Div 1 Groups C D T4
Class II Div 1 Groups F G T4

Rated Temp: 
-20°C ≤ Ta ≤ +85°C

Part numbers: Standard Sensor 403700, Intrinsically Safe Sensor 403699

Chesterton Connect Gauge™ Operating Parameters

Pressure sensor limit: -1 bar g – 68 bar g (-14.7 psig – 1000 psig)
Temperature: -20°C – 85°C (-4°F – 185°F) with the CR2050 battery
Power: Battery CR2050 (replaceable)
Fitting: 1/4" NPT
Material: 17-4PH and polycarbonate enclosure
Certifications: IP66/IP67, FCC, CE, RoHS
Pressure Accuracy: ±0.25%
Temprature Output Accuracy: ±3°C
Wireless: Bluetooth® 4.0

Chesterton Connect Gateway™ Operating Parameters*

Temperature: 1 bar g – 68 bar g (-14.7 psig – 1000 psig)
Power: -20°C – 85°C (-4°F – 185°F)
Wireless: -20°​C - 125°C (-4°F - 257°F)
Enclosure Rating: 3-axis accelerometer ±16g
Sensor Range: 3.6V lithium thionyl chloride battery (replaceable)
Sensor Support: 1/4" NPT 17-4PH connection
Mount: Magnetic mounting base (additional mounting options sold separately)
Certifications: FCC, IC, RoHS, IP66, NSF61, ACS
*Internet connectivity required.

Hazardous Areas Option

Certifications:

ATEX/IECEx:
3 (3) G Ex ec [ic Gc] nR IIC T6 Gc
3 D Ex ec ic tc IIIC T85°C Dc

cMETus:
Class I, Div 2, Groups A - D Class II
Div 2, Groups F - G

cMETus:
Class I, Zone 2 AEx ec ic nR IIC T6 Gc
Class II, Zone 22 AEx ec ic tc IIIC T85°C
Dc -40°C <= Tamb <= 60°C

Part numbers:  Standard Gateway 415198, Explosion Proof Gateway 414494

 
 

Let's talk

For inquires about products, sales, or requesting a quote, please contact our Sales Office.

Resources

  Name Download File type
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Chesterton Connect Cloud Submersible Pump Extended Case Study Ebook (English) 4715 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton 1510 Seal and Connect Monitoring Increase MTBR (English) 422 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect Sensor Detects Vacuum Malfunctions in Centrifugal Pump (English) 385 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect Sensor Helps Determine Cause of Costly Seal Failures (English) 482 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect System Helps Prevent Bearing Failures at Carbon Plant (English) 620 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect Sensor Solves System Issue - Chesterton Products Repair Pump (English) 479 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect System Detects Faulty Valve (English) 407 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect IS Sensor Determines Cause of Mixer Vibration (English) 553 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: New Pump Problem Solved with Chesterton Connect System (English) 358 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study: Chesterton Connect Sensor Reduces Submersible Pump Damage at Lift Station (English) 209 KB
.pdf
 Industry=Oil and Gas|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study 001 Equipment Monitoring - Gas Industry - Pump Process Issues Solved (English) 725 KB
.pdf
 Industry=Pulp and Paper|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study 002 Equipment Montoring - Paper Industry - Pump Vibration Issue (English) 714 KB
.pdf
 Industry=Chemical Processing|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Case Study 004: Equipment Monitoring - Chemical Industry -Sensor Identifies Mechanical Seal Failure 1256 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Chesterton Connect Case Study 005: Slurry Pump Solution (English) 1189 KB
.pdf
 Industry=Water Treatment|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Connect Case Study 007: Wastewater Pump Monitoring (English) 1532 KB
.pdf
 Industry=Chemical Processing|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Chesterton Connect Case Study 006: Chemical Industry S20 Seal Deliver Pump Reliability (English) 1974 KB
.pdf
  Name Download File type
 Industry=|Language=Svenska|LanguageId=sv|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Swedish) 1167 KB
.pdf
 Industry=|Language=Português|LanguageId=pt|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Portuguese) 1180 KB
.pdf
 Industry=|Language=Polski|LanguageId=pl|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Polski) 1076 KB
.pdf
 Industry=|Language=Italiano|LanguageId=it|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Italiano) 1165 KB
.pdf
 Industry=|Language=Français|LanguageId=fr|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (French) 1167 KB
.pdf
 Industry=|Language=Deutsch|LanguageId=de|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Deutsch) 1167 KB
.pdf
 Industry=|Language=Ceština|LanguageId=cz|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (Czech) 1167 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
User's Guide: Chesterton Connect Gauge (English) 652 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Installation Guide - Warranty: Chesterton Connect (English) 47 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Mobil App (English) 1525 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (English) 2798 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Quick Start (English) 1165 KB
.pdf
 Industry=|Language=Deutsch|LanguageId=de|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Mobile App (German) 6997 KB
.pdf
 Industry=|Language=Korean|LanguageId=ko|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Mobile App (Korean) 6821 KB
.pdf
 Industry=|Language=Español|LanguageId=es|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Setup Guide - Sensor, Gateway, and Cloud (Espanol) 5194 KB
.pdf
 Industry=|Language=English|LanguageId=en|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect Setup Guide - Sensor, Gateway, and Cloud (English) 5175 KB
.pdf
 Industry=|Language=Français|LanguageId=fr|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Francais) 2730 KB
.pdf
 Industry=|Language=Hungarian|LanguageId=hu|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Hungarian) 2708 KB
.pdf
 Industry=|Language=Italiano|LanguageId=it|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Italiano) 2409 KB
.pdf
 Industry=|Language=Polski|LanguageId=pl|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Polski) 2731 KB
.pdf
 Industry=|Language=Svenska|LanguageId=sv|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Svenksa) 2758 KB
.pdf
 Industry=|Language=Ceština|LanguageId=cz|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Czech) 2756 KB
.pdf
 Industry=|Language=Español|LanguageId=es|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Espanol) 2706 KB
.pdf
 Industry=|Language=Finnish|LanguageId=fi|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Finnish) 2697 KB
.pdf
 Industry=|Language=Deutsch|LanguageId=de|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Guide: Chesterton Connect User Guide (Deutsch) 2708 KB
.pdf
 Industry=|Language=Español|LanguageId=es|ProductLine=Rotating|MaterialCategory=|MaterialCode=
Quick Start Guide - Chesterton Connect (Espanol) 1208 KB
.pdf